RCP is an interface module between BMW factory equipped fuel fired heater (FFH) and control device. It allows
to connect almost any convenient remote control to FFH. |
|
1. Remote Start / Stop of the Heater by Remote Key |
|
|
Autoplugin RCP lets you immediately start and stop of fuel fired heater by original
remote key. It uses a combination of buttons presses to activate this function. And certainly, you can use
iDrive to program the heater, as you did it before. |
|
|
2. Variety of Remote Controls |
|
|
|
Autoplugin RCP has a set of inputs for easy connection of diverse remotes, like Webasto Telestart, Eberspächer
Easy Start, Defa Smart Start, GSM-modules (to control heater using mobile phone), alarm systems controls, etc. |
|
4. Startup and Operation Process Indication by Turn Signals Indicators |
|
Autoplugin RCP may flash by direction indicators to inform user that the heater started
and operates. It's adjustable function, which may be switched on or off (off set by default). |
|
5. Main Battery Protection from Discharging |
|
Fuel fired heater uses energy of the vehicle's main battery to operate, not only fuel. Autoplugin RCP may
control a level of battery voltage to prevent the battery from discharging.
The level can be adjusted in accordance of battery condition. Also you can limit time of autonomous work of the heater. |
|
6. Control of External Devices |
|
Autoplugin RCP allows you to control external devices while the heater operates. Functions and examples
of their use:
|
|
|
Disconnection of consumers during the heater operation to conserve battery power (for example, turning off the climate control fan) |
|
|
|
Disable highly sensitive sensors of additional alarm system to prevent false alarm triggering when the heater operates |
|
|
|
|
Art. N: |
0104-1100 |
|
|
Stock: |
Out Of Stock |
|
|
|
Models with factory equipped fuel fired heaters: |
|
|
|
3 (E90—E93) 2012—... |
|
|
|
5 (F10/F11/F18) 2010—... |
|
|
|
5 GT (F07) 2009—... |
|
|
|
7 (E65/E66) 2001—2008 |
|
|
|
7 (F01/F02) 2008—2015 |
|
|
|
X5 (E70) 2007—2013 |
|
|
|
X6 (E71) 2007—2014 |
|
|
|
|
|
|
|
Compatibility |
|
Models, factory equipped with Webasto fuel-fired heaters:
|
|
|
3 (E90/E91/E92/E93) 2012—... |
|
|
|
5 (F10/F11/F18) 2010—... |
|
|
|
5 GT (F07) 2009—... |
|
|
|
7 (E65/E66) 2001—2008 |
|
|
|
7 (F01/F02) 2008—2015 |
|
|
|
X5 (E70) 2007—2013 |
|
|
|
X6 (E71) 2007—2014 |
|
|
Implementation |
|
Electronic module for embedded installation
|
|
|
Permanent connection to the car wiring |
|
|
Main Functions of the Heater Control |
|
|
Immediate start of the heater by remote |
|
|
|
Immediate stop of the heater by remote |
|
|
Standard Remote Control |
|
|
|
Possibility to Use an Additional Remote Control |
|
Yes |
|
Possibility of the Heater Control by the Additional Button |
|
Yes
|
|
|
Immediate start of the heater by remote |
|
|
|
Immediate stop of the heater by remote |
|
|
Indication |
|
|
Indication of the heater successful start by turn signals indicators |
|
|
|
Indication of the heater unsuccessful start by turn signals |
|
|
|
Indication of the heater operation by turn signals indicators |
|
|
|
Indication of the heater run-time errors by built-in indicator |
|
|
Inputs & Outputs |
|
|
Separate inputs to the heater start and stop, controlled by short impulses of positive or negative polarity |
|
|
|
Additional input to the heater start / stop by specialized remote (Defa Smart Start, Telestart, Easy Start, GSM Module) |
|
|
|
Input for additional button |
|
|
|
The pare of inputs / outputs for alarm sensitive or volume sensors disabling,
during heater operation |
|
|
|
Two programmable outputs for notification of the heater working. A variety of signals
can be given on these outputs:
Heater has started
Heater started to heat
Heater stopped
Engine is warm
Heater doesn't start
Heater error
|
|
|
|
Programmable status output to control vehicle's modules, not available
by CAN-bus, during the heater operation (climate control module switching off in order to save battery
energy, etc.):
Heater operates
Heater operates autonomously (without engine)
Engine runs (potential signal)
Engine runs (RPM signal)
Ventilation switched on while the heater operates autonomously
Ventilation switched off while the heater operates autonomously
|
|
|
Main Battery Protection from Discharging |
|
|
Monitoring and limitation of time of autonomous work of the heater |
|
|
|
Monitoring of battery voltage before the heater start. It includes heater start
cancel and error indication in case of low voltage. Adjustable, off by default. |
|
|
|
Monitoring of battery voltage while the heater operates. It includes heater shutting
off and error indication in case of low voltage. Adjustable, off by default. |
|
|
The Heater Control Method |
|
Via CAN-bus |
|
Power Consumption |
|
1.5 mA |
|
Working Temperatures |
|
-40 °C ... +85 °C |
|
Dimensions & Weight |
|
|
|
What's in the Box |
|
|
Module |
|
|
|
Installation set |
|
|
|
Documentation (en) |
|
|
|
|
The RCP module does not have embedded radio signal receiver. The contol range will be identical to the car's key. |
|
|
Please complete and submit the form to make the order. |
|
We will send invoices through PayPal to your email. Usually, the orders are shipped within 2 working days after payment. |
|
We take orders and answer them manually. Sorry, it's possible delay in the response. |
|
Autoplugin RCP-B1 Module (0104-1100) |
Out Of Stock |
|
20,- Eur |
End user firmware license What for? |
|
157,- Eur |
|
|
|
|
We accept PayPal. It is safe and secure.
When transactions need only a login and password, you don’t
expose bank details or card numbers. It’s an added layer of protection for your financial information.
If something goes wrong
with an order, PayPal will investigate. If your transaction qualifies for Purchase Protection, PayPal will reimburse you for the full
purchase price plus any original shipping costs. |
|
|
|